We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
We have taken a novel approach using oral rapamycin – sirolimus – as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure.
Background
Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease.
Methods
Rapamycin was administered to 10 patients (1.5–18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1–3 months. Potential side-effects were monitored by clinical review and blood tests.
Results
Target serum rapamycin level (6–10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal.
Conclusions
Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.