We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To assess the effect on hearing of non-functioning ventilation tubes due to blockage during the first six months post-operatively, using UK national guidelines.
Method
A prospective, observational study was conducted on 37 children who underwent bilateral ventilation tube insertion. Air and bone conduction thresholds were measured before and following surgery, and at one, three and six months post-operatively. Tube non-function was assessed by tympanometry supported by otoscopy.
Results
Post-operatively, an average of 21 per cent of ventilation tubes were non-functioning. Ears with non-functioning tubes had significantly (p = 0.0001) poorer mean air conduction thresholds than functioning tubes, with a magnitude of 6 dB HL. Ears with otorrhoea were most affected (15 per cent). At any one visit, the air–bone gap was closed to 10 dB or less in 76 per cent of ears. Non-functioning tubes reduced this to 56 per cent. Compared with tympanometry, otoscopy underdiagnosed tube non-function due to blockage by 22 per cent.
Conclusion
Non-functioning of ventilation tubes occurs frequently and can be missed on otoscopy. Although it is associated with poorer air conduction thresholds, the magnitude of this difference is unlikely to warrant further intervention unless there is otorrhoea or recurrence of bilateral hearing impairment.