Efficacy of UV-C disinfection in hyperbaric chambers

Published online by Cambridge University Press:  17 June 2020

Bobby Glenn Warren*
Affiliation:
Duke Center for Antimicrobial Stewardship and Infection Prevention, Durham, North Carolina Division of Infectious Diseases, Duke University Medical Center, Durham, North Carolina
Jason Masker
Affiliation:
Duke Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Durham, North Carolina
Gregory Brown
Affiliation:
Duke Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Durham, North Carolina
Isabella Gamez
Affiliation:
North Carolina School of Science and Mathematics, Durham, North Carolina
Becky Smith
Affiliation:
Duke Center for Antimicrobial Stewardship and Infection Prevention, Durham, North Carolina Division of Infectious Diseases, Duke University Medical Center, Durham, North Carolina
Deverick J. Anderson
Affiliation:
Duke Center for Antimicrobial Stewardship and Infection Prevention, Durham, North Carolina Division of Infectious Diseases, Duke University Medical Center, Durham, North Carolina
Nicholas Turner
Affiliation:
Duke Center for Antimicrobial Stewardship and Infection Prevention, Durham, North Carolina Division of Infectious Diseases, Duke University Medical Center, Durham, North Carolina
*
Author for correspondence: Bobby Glenn Warren, E-mail: Bobby.warren@duke.edu.
Rights & Permissions [Opens in a new window]

Abstract

Ultraviolet C (UV-C) light reduces contamination on high-touch clinical surfaces. We assessed the efficacy of 2 UV-C devices at eradicating important clinical pathogens in hyperbaric chambers. Both devices were similarly efficacious against MRSA but differed significantly against C. difficile. Additionally, direct UV-C exposure was more efficacious against both species than indirect exposure.

Type
Concise Communication
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.

Contaminated healthcare environmental surfaces contribute to pathogen transmission. Among the UV-C disinfection studies conducted in clinical settings, results have been mixed, perhaps in part due to heterogeneity in device design, protocols for use, and application within real-world clinical settings.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce1,Reference Boyce and Donskey2 Testing individual products in clinical environments before deploying them in healthcare facilities is critical.Reference Huffman, Webb and Spina3,Reference Schulz-Stübner, Kosa, Henker, Mattner and Friedrich4 Additionally, few studies have tested UV-C devices in specialized healthcare settings such as hyperbaric chambers. In this study, we evaluated the efficacy of 2 UV-C devices for disinfection of surfaces contaminated with epidemiologically important pathogens (EIPs) in hyperbaric chambers of varying shapes.

Methods

We assessed the efficacy of the Tru-D (SmartUVC) and Moonbeam-3 (Diversey) UV-C devices at eradicating EIPs in 2 hyperbaric chambers at Duke University Health System in Durham, North Carolina.

For MRSA, bacterial suspensions were prepared by incubating in tryptic soy broth (TSB) at 37°C until reaching an optical density at 600 nm (OD600) of 0.8 and serially diluting them. For Clostridioides difficile, bacterial suspensions were prepared by resuspending 48-hour growth from anaerobically incubated trypticase soy agar (TSA) blood agar in phosphate-buffered saline and diluting it to a prestandardized OD600. We inoculated 10×10-cm Formica sheets with 106–107 colony-forming units (CFU) of methicillin-resistant Staphylococcus aureus (MRSA, USA300) or 104–105C. difficile (NAP1; BEI Resources, NIH isolate no. 20120236). Inocula were spread on the center 25 cm2 of the Formica sheets and were allowed to dry for 5 minutes. Inoculated sheets were placed in 6 predetermined locations throughout each of 2 hyperbaric chambers (chambers A and C). Inoculated control plates remained outside the chambers during disinfection and sampled alongside inoculated sheets.

Chamber A was a 2-hatched cylinder with a diameter of 6 m (19’6”) and a length of 4.4 m (14’6”). Chamber C was a 3-hatched spherical chamber 6 m (20’) in diameter. In chamber A, inoculated Formica sheets were placed on the regulator connection area, which received direct UV-C for Tru-D experiments (direct exposure) and indirect UV-C for Moonbeam-3 experiments (indirect exposure), patient chair armrest (direct exposure), medlock (indirect exposure), chamber door handle (direct exposure), medical supply cart (direct exposure), and the underside of the patient chair side table (indirect exposure). In chamber C, the locations and exposure pathways were the same, except the medlock was replaced with the sink (direct exposure). Samples were placed between 0.6 m (2’) and 1.5 m (5’) away from the UV-C device in chamber A and between 1.2 m (4’) and 3 m (10’) from the UV-C device in chamber C. Each sample site was defined as receiving direct UV-C exposure if a straight line could be extended from a UV-C bulb to the sample site uninterrupted, otherwise it was defined as receiving indirect exposure.

For this experiment, 2 Moonbeam-3 UV-C devices were positioned in the center of each chamber back to back, with each bulb at a 45° angle from the center of the device, and was run for a 3-minute cycle (according to the manufacturer’s instructions) and a 5-minute cycle. One Tru-D was positioned in the center of the chamber center and was then run on the vegetative cycle for MRSA and the spore cycle for C. difficile. UV-C irradiance was measured for both machines at each sample location using 2 different quantitative radiometers (Grainger, Raleigh NC), and dosages were calculated. Quantitative cultures were collected using RODAC plates with DE neutralizing agar. The C. difficile was replica plated onto prereduced TSA sheep’s blood agar. Both were incubated at 37°C for 48 hours. Each combination of chamber, microbe, UV-C device, and device cycle was run in triplicate for a total of 108 samples per species.

The independent t test was used to compare CFU log10 reductions among cycles, machines, and exposure pathways. A P value of .05 was considered significant. All statistical tests were 2-tailed and were conducted using R software (R Foundation for Statistical Computing, Vienna, Austria).

Results

UV-C dosages

The mean UV-C dosages of the 3- and 5-minute Moonbeam-3 cycles were 7,403 and 12,338 µWs/cm2, respectively (Fig. 1). The direct and indirect UV-C dosages achieved with the 3-minute cycle were 10,813 and 3,510 µWs/cm2, respectively, and with the 5-minute cycle, 16,971 and 5,850 µWs/cm2, respectively (Fig. 2).

Fig. 1. Colony-forming units (CFU) log10 reduction and ultraviolet C (UV-C) dosage.

Fig. 2. (a) Direct ultraviolet C (UV-C) exposure colony-forming units (CFU) log10 reduction and UV-C dosage. (b) Indirect UV-C exposure CFU log10 reduction and UV-C dosage.

The mean UV-C dosage of the Tru-D spore cycle (mean time, 17 minutes) was 104,041 µWs/cm2, and the mean UV-C dosage of Tru-D vegetative cycle (mean time, 9 minutes) was 57,705 µWs/cm2 (Fig. 1). With the Tru-D spore cycle, the direct UV-C dosage achieved was 152,557 µWs/cm2 and the indirect UV-C dosage achieved was 55,525 µWs/cm2. With the Tru-D vegetative cycle, the direct UV-C dosage achieved was 83,882 and the indirect UV-C dosage achieved 31,812 µWs/cm2, respectively (Fig. 2).

MRSA

The Tru-D vegetative cycle resulted in an average CFU log10 reduction of 7.02 (95% CI, 7.02–7.02), the 3-minute Moonbeam-3 cycle resulted in an average CFU log10 reduction of 6.58 (95% CI, 6.37–6.79), and the 5-minute Moonbeam-3 cycle resulted in an average CFU log10 reduction of 6.99 (95% CI, 6.95–7.02) (Fig. 1). The Tru-D vegetative cycle and the 5-minute Moonbeam-3 cycle were similarly efficacious (P > .99), and both were more efficacious than the 3-minute Moonbeam-3 cycle (P < .001, P < .001, respectively). The MRSA samples subjected to direct UV-C exposure showed significantly greater log10 reductions (6.95; 95% CI, 6.89–7.01) than those subjected to indirect exposure (6.67; 95% CI, 6.46–6.87; P < .05) (Fig. 2).

Clostridioides difficile

The Tru-D sporicidal cycle resulted in an average CFU log10 reduction of 1.78 (95% CI, 1.43–2.12), the 3-minute Moonbeam-3 cycle resulted in an average CFU log10 reduction of 0.57 (95% CI, 0.33–0.81), and the 5-minute Moonbeam-3 cycle resulted in an average CFU log10 reduction of 0.64 (95% CI, 0.42–0.86) (Fig. 1). The Tru-D sporicidal cycle was significantly more effective than either the 3-minute Moonbeam-3 cycle or the 5-minute Moonbeam-3 cycle (P < .01). The C. difficile samples receiving direct UV-C exposure had significantly greater log10 reductions (1.34; 95% CI, 1.10–1.58) than those receiving indirect exposure (0.58, 95% CI, 0.31–0.86; P < .01) (Fig. 2).

Discussion

UV-C light reduces contamination of high-touch clinical surfaces, yet more studies are needed to test the comparative efficacy of UV-C devices in real-world clinical environments.Reference Haas, Menz, Dusza and Montecalvo5-Reference Masse, Hartley, Edmond and Diekema7 We tested the efficacy of 2 UV-C devices in clinical hyperbaric chambers. The use of the Tru-D vegetative cycle and the 5-minute Moonbeam cycle resulted in similar reductions in MRSA; both resulted in significantly larger reductions than the manufacturer’s recommended 3-minute Moonbeam-3 cycle. For C. difficile, the Tru-D sporicidal cycle was significantly more efficacious than either of the Moonbeam-3 cycles; however, neither device approached the >3 log10 threshold. Therefore, healthcare facilities should re-evaluate manufacturer-recommended run times in their specific clinical setting. If possible, hospitals should test different machines in their own facilities and varying room configurations. Direct UV-C exposure resulted in greater average reductions than indirect exposure, which is likely due to the large differences in UV-C dosage. In addition to manufacturer’s instructions, run time, path of UV-C exposure, resultant UV-C dosage, and pathogen type are key components to consider when designing facility-specific recommendations.

Previous studies have shown the potential of UV-C as a disinfectant in controlled environments, but it is imperative to test UV-C in the real-world clinical environment.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce1 In a previous clinical trial, we demonstrated the benefit of Tru-D UV-C disinfection in addition to routine cleaning, but no clinical trials including patient outcomes have evaluated the Moonbeam-3 or other UV devices.Reference Anderson, Moehring and Weber8 Our log10 reductions of 6 or higher for MRSA are larger than those of prior studies, most likely due to differences in inoculum size.Reference Boyce, Farrel, Towle, Fekieta and Aniskiewicz9,Reference Alhmidi, Cadnum, Piedrahita, John and Donskey10

Our study has several limitations. We sampled Formica sheets instead of sampling directly from clinical surfaces. We evaluated only 2 pathogens, and our experimented lacked contamination simulation (eg, concomitant organic load or co-contaminants). Because our experiments were conducted in hyperbaric chambers, the results may not be generalizable to other contexts. Subsequent trials should further evaluate UV-C for disinfection by replicating the real-world clinical environment as accurately as possible.

In conclusion, UV-C disinfection can be efficacious in hyperbaric chambers by reducing the levels of clinically relevant bacteria by at least 3 log10, but individual UV-C devices should be tested and optimized internally while also recognizing that similar efficacy may not be achieved with certain pathogens such as C. difficile.Reference Boyce and Donskey2

Acknowledgments

We thank Lilliah Taschuk from Diversey for providing Moonbeam-3 devices and Jessica Doyle from Duke Hospital’s UV team for providing the Tru-D devices.

Financial support

All financial support was institutional.

Conflicts of interest

No authors report any conflicts of interest.

Footnotes

PLANNED PRESENTATION: This data was accepted as an abstract for a poster presentation at SHEA 2020, which has not yet been scheduled.

References

Weber, DJ, Rutala, WA, Anderson, DJ, Chen, LF, Sickbert-Bennett, EE, Boyce, JM.Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: focus on clinical trials. Am J Infect Control 2016;44:e77e84.10.1016/j.ajic.2015.11.015CrossRefGoogle ScholarPubMed
Boyce, JM, Donskey, CJ.Understanding ultraviolet light surface decontamination in hospital rooms: a primer. Infect Control Hosp Epidemiol 2019;40:10301035.10.1017/ice.2019.161CrossRefGoogle ScholarPubMed
Huffman, S, Webb, C, Spina, SP.Investigation into the cleaning methods of smartphones and wearables from infectious contamination in a patient care environment (I-SWIPE). Am J Infect Control 2020;48:545549.10.1016/j.ajic.2019.09.009CrossRefGoogle Scholar
Schulz-Stübner, S, Kosa, R, Henker, J, Mattner, F, Friedrich, A.Is UV-C light wand mobile disinfection in air ambulance helicopters effective? Infect Control Hosp Epidemiol 2019;40:13231326.10.1017/ice.2019.225CrossRefGoogle ScholarPubMed
Haas, JP, Menz, J, Dusza, S, Montecalvo, MA.Implementation and impact of ultraviolet environmental disinfection in an acute care setting. Am J Infect Control 2014;42:586590.10.1016/j.ajic.2013.12.013CrossRefGoogle Scholar
Cadnum, JL, Jencson, AL, Gestrich, SA, et al.A comparison of the efficacy of multiple ultraviolet light room decontamination devices in a radiology procedure room. Infect Control Hosp Epidemiol 2019;40:158163.10.1017/ice.2018.296CrossRefGoogle Scholar
Masse, V, Hartley, MJ, Edmond, MB, Diekema, DJ.Comparing and optimizing ultraviolet germicidal irradiation systems use for patient room terminal disinfection: An exploratory study using radiometry and commercial test cards. Antimicrob Resist Infect Control 2018;7:17.10.1186/s13756-018-0317-1CrossRefGoogle ScholarPubMed
Anderson, DJ, Moehring, RW, Weber, DJ, et al.Effectiveness of targeted enhanced terminal room disinfection on hospital-wide acquisition and infection with multidrug-resistant organisms and Clostridium difficile: a secondary analysis of a multicentre cluster randomised controlled trial with crossover design (BETR Disinfection). Lancet Infect Dis 2018;18:845853.10.1016/S1473-3099(18)30278-0CrossRefGoogle Scholar
Boyce, JM, Farrel, PA, Towle, D, Fekieta, R, Aniskiewicz, M.Impact of room location on UV-C irradiance and UV-C dosage and antimicrobial effect delivered by a mobile UV-C light device. Infect Control Hosp Epidemiol 2016;37:667672.10.1017/ice.2016.35CrossRefGoogle ScholarPubMed
Alhmidi, H, Cadnum, JL, Piedrahita, CT, John, AR, Donskey, CJ.Evaluation of an automated ultraviolet-C light disinfection device and patient hand hygiene for reduction of pathogen transfer from interactive touchscreen computer kiosks. Am J Infect Control 2018;46:464467.10.1016/j.ajic.2017.09.032CrossRefGoogle ScholarPubMed
Figure 0

Fig. 1. Colony-forming units (CFU) log10 reduction and ultraviolet C (UV-C) dosage.

Figure 1

Fig. 2. (a) Direct ultraviolet C (UV-C) exposure colony-forming units (CFU) log10 reduction and UV-C dosage. (b) Indirect UV-C exposure CFU log10 reduction and UV-C dosage.