Article contents
Non-Destructive Measurements of III-V Semiconductor Device Structure by a Hard X-ray Microprobe
Published online by Cambridge University Press: 26 February 2011
Abstract
A non-destructive characterization technique featuring a hard X-ray Microprobe is demonstrated for lll-V semiconductor device structures. A GaAs FET with a 2 μm gate length is measured as a model sample of a thin film structure. X-ray scanning microscopic images of the FET are obtained by diffracted X-ray and fluorescence X-ray detection. Diffracted X-ray detection measures the difference in gate material and source or drain material as a gray level difference on the image due to the X-ray absorption ratio. Ni Ka fluorescence detection, on the other hand, provides imaging of 500 Å thick Ni layers, which are contained only in the source and drain metals, through non-destructive observation.