Hostname: page-component-745bb68f8f-kw2vx Total loading time: 0 Render date: 2025-02-11T15:33:50.958Z Has data issue: false hasContentIssue false

Advanced 20 TW Ti:S laser system for X-ray laser and coherent XUV generation irradiated by ultra-high intensities

Published online by Cambridge University Press:  07 June 2005

HIROTO KURODA
Affiliation:
The Institute for Solid State Physics, The University of Tokyo, Chiba, Japan
MASAYUKI SUZUKI
Affiliation:
The Institute for Solid State Physics, The University of Tokyo, Chiba, Japan
RASHID GANEEV
Affiliation:
The Institute for Solid State Physics, The University of Tokyo, Chiba, Japan
JUN ZHANG
Affiliation:
The Institute for Solid State Physics, The University of Tokyo, Chiba, Japan
MOTOYOSHI BABA
Affiliation:
The Institute for Solid State Physics, The University of Tokyo, Chiba, Japan
TSUNEYUKI OZAKI
Affiliation:
Institut national de la recherche scientifique, Quebec, Canada
ZHI YI WEI
Affiliation:
Laboratory of Optical Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, People's Republic of China
JIE ZHANG
Affiliation:
Laboratory of Optical Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, People's Republic of China
Rights & Permissions [Opens in a new window]

Abstract

In order to develop a high repetition rate X-ray lasers, the longitudinal-pumped transient collisional excitation (TCE) X-ray laser is one of the most effective pumping schemes. The high directive Ni-like Mo 18.9 nm soft X-ray laser pumped by modest laser energy has already been demonstrated by using the tabletop size Ti:sapphire/Nd:glass laser system that delivering energy of 150 mJ in 475 fs at the center wavelength of 1054 nm. The total energy in the pre-pulse and the main pulse was 150 mJ, which will make possible multi-hertz operation. To pursue the high repetition rate of the laser-driven TCE X-ray laser, we have designed a new 20 TW Ti:Sapphire laser system (600 mJ, 30 fs, 10 Hz). Special attention was paid to improve the contrast ratio, control of pulse shape as well as phase by an acoustic optic programmable dispersive filter (AOPDF) and 1 kHz preamplifier. Preliminary data have shown good laser characteristics. As the preliminary experiments, we have investigated high order harmonics generation from low-density laser plasma by using the solid target irradiated by a femtosecond laser pulse. The highest order was the 51st. harmonic at wavelength of 15.61 nm.

Type
Research Article
Copyright
2005 Cambridge University Press

1. INTRODUCTION

So far, extensive studies have been devoted to develop coherent X-ray and extreme ultraviolet (XUV) laser generation, which are expected to open new fields in physics, chemistry, and biophysics (Neumayer et al., 2005; Lan et al., 2004; Bellini et al., 2004; Merdji et al., 2004; Morlens et al., 2004) . Development of high repetition rate X-ray laser is an important factor for a real application experiment. Recently, capillary discharge (Benware et al., 2001) and optical-field ionization schemes (Sebban et al., 2002) have achieved the high repetition rate X-ray laser generation. The longitudinal-pumped TCE X-ray laser and XUV generation from femtosecond laser produced solid surface plasma were studied in our group (Ganeev et al., 2004; Ishizawa et al., 2002; Kuroda et al., 2002a or b; Li et al., 1998; Ozaki et al., 2002a, b, c, d). Since the development of high directive Ni-like Mo 18.9 nm soft X-ray laser pumped longitudinally by only total 150 mJ laser (Ozaki et al., 2002a, b, c, d), there has been strong interest in making tabletop soft X-ray laser pumped by such modest energy and equipped with qualified laser characteristics. In order to develop the high repetition rate of the laser-driven TCE X-ray laser, the longitudinal-pumped TCE X-ray laser is the most effective pumping scheme. In our demonstration, the new aspects of pulse shape control (energy and duration of pedestal), and concave electron density are discussed and compared with simulations of X-ray laser propagation (Ozaki et al., 2002a, b, c, d). Recently, Keenan et al. (2003) reported a different scheme using traveling wave grazing incidence pumping. They showed the Ni-like Mo 18.9 nm lasing pumped by total 300 mJ (main pulse 70 mJ) of which energy is 1/20 of usual transverse pumping. Nickels also reported on the success to reduce the pumping energy by a factor 1/5–1/6 by changing the shape of pump pulses, including its shape, and amplitude of pedestals (Janulewicz et al., 2004). It is an important factor of the pedestal, contrast ratio, and phase of laser pulse to generate the TCE X-ray laser.

In this paper, we report the investigation on the longitudinally pumping TCE X-ray lasers and high order harmonic generations from solid surface of plasmas. According to results from our investigations, we have designed a new 20 TW Ti: Sapphire laser system (600 mJ, 30 fs, 10 Hz) and describe the necessity of its new technology for high repetition X-ray lasers. As the preliminary experiments, we investigated high order harmonics generation from low-density laser plasma by using the solid target irradiated by a femtosecond laser pulse. We show the preliminary results of this experiment.

2. NEW 20 TW LASER SYSTEM DESIGN AND PERFORMANCE

Layout of the 20 TW Ti:Sapphire laser system (Ultra-laser Inc. Beijing) presently under construction at our laboratory is shown in Figure 1. The whole of tabletop 20 TW Ti:Sapphire laser system consists of a femtosecond oscillator, an Offner-type stretcher, an AOPDF, a kHz regenerative amplifier, a 6-pass main amplifier, and a vacuum pulse compressor. Special attention was paid to improve the contrast ratio and control of pulse shape, and phase by adaptive AOPDF and 1 kHz preamplifier. Preliminary data have shown good laser characteristics. The femtosecond oscillator is pumped by a compact solid-state diode-pumped, frequency-doubled Nd:Vanadate (Nd:YVO4) laser (Verdi-V8, Coherent Inc.) that provides single-frequency green (532 nm) output with maximum power of 8 W. The oscillator with 1.1 W output power and pulse width of 30 fs pulse duration at 83 MHz repetition rate is obtained for a 6.5 W pump power of the Verdi-V8. The FWHM spectral bandwidth of 48 nm is obtained for the center wavelength of 800 nm. The short pulse from the oscillator is stretched to 300 ps by the Offner-type stretcher. In order to control the dispersion and shaping of the laser pulse, the AOPDF (800 WB-AT, Fastlite, Inc.) was installed after the Offner-type stretcher (Monmayrant et al., 2003). The AOPDF can control the pedestal and shape of the laser pulse in X-ray and XUV laser experiments. Figure 2 shows the laser spectrum shape controlled by the AOPDF. To improve the stability of laser and contrast ratio, the regenerative amplifier was operated at 1 kHz repetition rate. This also allows a beam pattern with high quality. The stretched pulse is amplified to 3 W by the 1 kHz Ti:Sapphire regenerative amplifier which pumped by a diode-pumped laser providing average power in excess of 20 W at second harmonics wavelength of Nd: YLF (JADE, THALES LASER). The amplifier with ∼2.3 W output power is obtained with 15 W pump power of JADE. The amplified pulse from the regenerative amplifier, change the 1 kHz to a 10 Hz repetition rate by using the Pockels cell. The 10 Hz laser pulse from the Pokels cell is amplified to 1.2 J with the 6-pass Ti: Sapphire amplifier pumped by using two Nd: YAG lasers (Spectra Physics PRO350), which provides pump laser energy of 1.4 J in 8 ns pulse at a wavelength of 532 nm. The pulse compressor is composed of two gratings of 1800 lines/mm in a vacuum chamber. The compressed pulse width is 30 fs by measuring the second order auto-correlation. In our estimations, the laser would generate more than 20 TW after compression.

Layout of the 20 TW Ti:Sapphire laser system. The system consists of a femtosecond oscillator, a free abbreviate stretcher, an AOPDF, a kHz regenerative amplifier, a 6-pass main amplifier, and a vacuum pulse compressor.

Spectra property of the laser pulse from AOPDF. Using the AOPDF, the spectra shape can be controlled.

3. HIGH ORDER HARMONIC GENERATION FROM LOW DENSITY LASER PLASMA

Experimental setup is shown in Figure 3. The 210 ps laser pre-pulse was focused onto the boron (Z = 5) target by using the spherical lens. After that the femtosecond main pulse (150 fs) was focused from longitudinal direction on the pre-plasma. The diameter of focal spot of pre-pulse was 0.6 mm. The delay between main pulse and pre-pulse duration was 18 ns. The pump energies of the pre-pulse and main pulse were 18 and 10 mJ, respectively. The generated harmonics were measure by a Hitachi 1200 grooves/mm flat-field soft X-ray spectrometer (Kita et al., 1983.) equipped with micro channel plate (MCP) and CCD camera.

Schematic of experimental setup on high order harmonic generation. The delay time between pre-pulse and main pulse was 18 ns. The main pulse was focused onto the position 0.1 mm above boron target.

Figure 4 shows the intensity trace of high order harmonic generation from boron laser plasma. The highest order was the 51st at the wavelength of 15.61 nm. We measured between 3rd 11th harmonics by using ACTON VM-502 vacuum monochromator. Only odd harmonics were obtained in this experiment. The physical mechanism is now investigated and will be published elsewhere.

(a) Harmonic spectrum from boron target plasma. The harmonic order between 15th and 51st at the wavelength from 15.61 nm to 53.06 nm were observed. (b) Soft X-ray generations from Boron laser plasma were obtained.

4. SUMMARY

In order to develop the high repetition rate X-ray laser, the longitudinal-pumped TCE X-ray laser is one of the most effective pumping schemes. We have described the results of longitudinally pumping TCE X-ray laser and high order harmonic generation from the solid surface plasma. The most important factor of the longitudinally pumping X-ray generations is concave density profile of pre-plasma and pedestal of the pumping laser pulse. To pursue the high repetition rate of the laser-driven TCE X-ray laser, we have designed a new 20 TW Ti:Sapphire laser system (600 mJ, 30 fs, 10 Hz). Special attention was paid to improve the contrast ratio and control of pulse shape and phase by adaptive AOPDF and 1 kHz preamplifier. As the preliminary experiments, we have investigated high order harmonics generation from a low density laser plasma by using the solid target irradiated by a femtosecond laser pulse. The highest order was the 51st harmonic at wavelength of 15.61 nm. The physical mechanism is now investigated and will be published elsewhere.

ACKNOWLEDGMENTS

The authors would like to acknowledge A. Ishizawa for the early stage of harmonics experiments and Z. Wang, W. Lin, and P. Wang for the development of the 20 TW laser systems. This work was partly supported by the Grant-in-Aid for Creative Scientific Research (14GS0206) of Japan Society for the Promotion of Science (JSPS).

Footnotes

This paper was presented at the 28th ECLIM conference in Rome, Italy.

References

REFERENCES

Bellini, M., Cavalieri, S., Corsi, C.,et al. (2004). High resolution spectroscopy in the XUV with pairs of mutually coherent and time-delayed laser harmonics Laser Part. Beams 22, 199202.Google Scholar
Benware, B.R., Seminario, M., Lecher, A.L.,et al. (2001). Generation and application of a high-average-power polarized soft-X-ray laser beam. J. Opt. Soc. B. 18, 10411045.CrossRefGoogle Scholar
Földes, I.B., Kocsis, G., Racz, E.,et al. (2003). Generation of high harmonics in laser plasmas Laser Part. Beams 21, 517521.Google Scholar
Ganeev, R.A., Teruo, K., Ishizawa, A.,et al. (2004). Development and applications of a compact hybrid tabletop terawatt chirped-pulse amplification Ti:sapphire-Nd:glass for X-ray lasing and harmonic generation. Appl. Opt. 43, 13961403.CrossRefGoogle Scholar
Ishizawa, A., Ozaki, T., Ganeev, R.A. & Kuroda, H. (2002). Measurement of blue shifts due to collisionless absorption in harmonic generation from subpicosecond laser-produced plasmas. Phys. Rev. E 66, 026414.Google Scholar
Janulewicz, A., Nickles, P.V., King, R.E. & Pert, G.J. (2004). Influence of pump on a transient collisionally pumped Ni-like Ag X-ray laser. Phys. Rev. A. 70, 013804.CrossRefGoogle Scholar
Kanai, T., Yamamoto, K., Li, R. & Zhang, J. (2002a). Coherent short wavelength radiation via picosecond Nd : glass lasers. Laser Part. Beams 20, 5965.Google Scholar
Keenan, R., Dunn, J., Shlyaptsev, V.N.,et al. (2003). Efficient pumping schemes for high average brightness collisional X-ray lasers. SPIE 5197, 213219.Google Scholar
Kita, T., Harada, T., Nakano, N. & Kuroda, H. (1983). Mechanically ruled aberration-corrected concave gratings for a flat-field grazing-incidence spectrograph. Appl. Opt. 22, 512513.CrossRefGoogle Scholar
Kuroda, H., Ozaki, T., Ishizawa,et al. (2002b). Studies of advanced soft X-ray laser and coherent higher harmonic generation using intense subpicosecond laser produced high density plasma. J. Luminescence 100, 291300.Google Scholar
Li, R., Ozaki, T., Kanai, T. & Kuroda, H. (1998). Proposal of a longitudinally pumped saturated Ni-like Mo ion X-ray laser at 18.9 nm. Phys Rev. E. 57, 7093.CrossRefGoogle Scholar
Lan, K., Fill, E. & Meyer-Ter-Vehn, J. (2004). Photopumping of XUV lasers by XFEL radiation. Laser Part. Beams 22, 261266.CrossRefGoogle Scholar
Merdji, H., Hergott, J.F., Kovacev, M., Priori, E., Salieres, P. & Carra, B.. (2004). Manipulating intense XUV coherent light in the temporal domain. Laser Part. Beams 22, 275278.Google Scholar
Monmayrant, A., Joffre, M., Oksenhendler, T.,et al. (2003). Time dominant interferometric for direct electric-field reconstruction by use of an acousto-optic programmable filter and a two-photon detector. Opt. Lett. 28, 278280.CrossRefGoogle Scholar
Morlens, A.S, Zeitoun, P., Vanbostal, L., Mercere, P., Faivre, G., Hubert, S., Troussel, P., Remond, C., Marmoret, R., Delmotte, F., Ravet, M.F. & Rouillay, M. (2004). Study of XUV beam splitter flatness for use on a Michelson interferometer. Laser Part. Beams 22, 279284.Google Scholar
Neumayer, P., Bock, R., Borneis, S., Brambrink, E.,et al. (2005). Status of PHELIX laser and first experiments. Laser Part. Beams 23 (in print).CrossRefGoogle Scholar
Ozaki, T., Nakano, H. & Kuroda, H. (2002a). Prepulse-produced plasma waveguide for longitudinally pumped nickellike molybdenum X-ray lasers. J. Opt. Soc. B 19, 13351341.Google Scholar
Ozaki, T., Yamamoto, K., Kanai, T. & Kuroda, H. (2002b). Jetlike structure in the visible emission of plasma pumped by an obliquely incident picosecond laser. J. Phys. Soc. (Japan) 71, 29632968.Google Scholar
Ozaki, T., Ganeev, R.A., Ishizawa, A.,et al. (2002c). High Directive 18.9 nm Nickel-like Molybdenum X-ray Laser Operating at 150 mJ Pump Energy. Phys. Rev. Lett. 89, 253902.Google Scholar
Ozaki, T., Nakano, H. & Kuroda, H. (2002d). Effects of pump propagation and absorption on the gain distribution of longitudinally pumped Ni-like molybdenum X-ray lasers. Phys. Rev. E 66, 047402.Google Scholar
Ros, D., Jamelot, G., Carllon, A.,et al. (2002). State of the development of X-ray lasers and applications at LSAI. Laser Part. Beams 20, 2330.CrossRefGoogle Scholar
Sebban, S., Mocek, Ros, D.,et al. (2002). Demonstration of a Ni-like Kr Optical-Field-Ionization Collisional Soft X-ray Laser at 32.8 nm. Phys. Rev. Lett. 89, 253901.CrossRefGoogle Scholar
Figure 0

Layout of the 20 TW Ti:Sapphire laser system. The system consists of a femtosecond oscillator, a free abbreviate stretcher, an AOPDF, a kHz regenerative amplifier, a 6-pass main amplifier, and a vacuum pulse compressor.

Figure 1

Spectra property of the laser pulse from AOPDF. Using the AOPDF, the spectra shape can be controlled.

Figure 2

Schematic of experimental setup on high order harmonic generation. The delay time between pre-pulse and main pulse was 18 ns. The main pulse was focused onto the position 0.1 mm above boron target.

Figure 3

(a) Harmonic spectrum from boron target plasma. The harmonic order between 15th and 51st at the wavelength from 15.61 nm to 53.06 nm were observed. (b) Soft X-ray generations from Boron laser plasma were obtained.