Extensive work has been published on rectal temperature (RT) to identify early post-partum illness (Drillich et al. Reference Drillich, Beetz, Pfützner, Sabin, Sabin, Kutzer, Nattermann and Heuwieser2001; Wenz et al. Reference Wenz, Moore and Kasimanickam2011), oestrus (Wrenn et al. Reference Wrenn, Bitman and Sykes1958; Rajamahendran et al. Reference Rajamahendran, Robinson, Desbottes and Walton1989), parturition (Wrenn et al. Reference Wrenn, Bitman and Sykes1958, Reference Wrenn, Bitman and Sykes1961) and heat stress (Suthar et al. Reference Suthar, Burfeind, Bonk, Voigtsberger, Keane and Heuwieser2012a) in dairy cows. Recently, confounders such as inter or intra-observer variability, thermometer and penetration depth have been demonstrated to affect the repeatability of RT measurements (Burfeind et al. Reference Burfeind, von Keyserlingk, Weary, Veira and Heuwieser2010). To obtain body temperature (BT) measurements in higher frequency without human interference, automatic monitoring methods for BT were used. These included surgical implantation of digital thermistors (Bitman et al. Reference Bitman, Lefcourt, Wood and Stroud1984) or transmitters with radio-telemetry units (Lammoglia et al. Reference Lammoglia, Bellows, Short, Bellows, Bighorn, Stevenson and Randel1997; Lefcourt & Adams, Reference Lefcourt and Adams1998; AlZahal et al. Reference AlZahal, AlZahal, Steele, Van Schaik, Kyriazakis, Duffield and McBride2011) in various anatomical locations (i.e. subcutaneously at the left flank, peritoneal cavity, udder, rumen). These approaches provided valuable insights into regulation of BT but were invasive and the equipment cumbersome. Therefore, non-surgical methods utilized BT monitoring units fitted into the rectum with a harness (Reuter et al. Reference Reuter, Carroll, Hulbert, Dailey and Galyean2010), placed in the rumen (Rose-Dye et al. Reference Rose-Dye, Burciaga-Robles, Krehbiel, Step, Fulton, Confer and Richards2011), the reticulum (Bewley et al. Reference Bewley, Einstein, Grott and Schutz2008) or tympanic cavity in the middle ear (Bergen & Kennedy, Reference Bergen and Kennedy2000).
Our group (Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010; Burfeind et al. Reference Burfeind, Suthar, Voigtsberger, Bonk and Heuwieser2011; Suthar et al. Reference Suthar, Burfeind, Patel, Dhami and Heuwieser2011) and others (Kendall et al. Reference Kendall, Nielsen, Webster, Verkerk, Littlejohn and Matthews2006; Dikmen et al. Reference Dikmen, Alava, Pontes, Fear, Dikmen, Olson and Hansen2008; Kendall & Webster, Reference Kendall and Webster2009) have successfully used vaginal data loggers for continuous monitoring of BT. Recently, this approach has been validated in vitro and in vivo (Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010). RT was measured in vivo with a digital thermometer at 3-h intervals and compared with an average vaginal temperature (VT) calculated from 18 observations measured over the corresponding 3-h interval. Coefficients of correlation for peak lactating and sick post-partum cows were 0·46 and 0·75, respectively. The coefficient of correlation between RT and VT was found to be increased (r=0·85, P<0·001) when the two measurements were separated by less than 10 min. Interestingly the coefficient of correlation between RT and VT was found to be less related (r=0·72, P<0·001) when the two measures were separated by 20 min. In this study VT of early post-partum healthy (n=7 cows) and with retained placenta (n=7 cows) and peak lactating (n=13 cows) was 0·0–0·1±0·1 °C greater than RT. For dry cows and lactating, non-pregnant cows the relationship between RT and VT was 0·76–0·89 and 0·71–0·86, respectively (Burfeind et al. Reference Burfeind, Suthar, Voigtsberger, Bonk and Heuwieser2011; Suthar et al. Reference Suthar, Burfeind, Bonk, Dhami and Heuwieser2012b). In both studies VT was 0·2±0·05 °C to 0·2±0·2 °C greater than RT.
All these studies measured VT in 5–10-min intervals and calculated means for 1–4-h intervals to demonstrate associations with RT measured hourly to every 4 h. This approach, albeit plausible, might affect the reported associations. Furthermore, most authors have used a digital thermometer to measure RT for validation of vaginal, reticular, ruminal or udder temperature monitored with data loggers or radio transmitters. Thus the reported correlations between two anatomical locations were biased by two different technologies. Therefore the objective of this study was to evaluate agreement between RT and VT measured with identical temperature data loggers.
Materials and methods
Three experiments were conducted between September and November 2011. All procedures for this study were in accordance with the Institutional Animal Care and Use Committee.
Experiment 1
The study began with an in-vitro phase evaluating variation among loggers. Twenty four different microprocessor controlled temperature loggers (Minilog 8, Vemco Ltd., Halifax, Canada; Size=92 mm×20 mm; weight=40·5 g) and a calibrated liquid-in-glass thermometer (validated by the Office of Legal Metrology of the State of Hessen, Germany; Type E 0.1/0/50 DIN 12775; Serial number 3636; Verification Certificate 5-3636-09) were placed into the same water bath (Julabo, Thermostate Electron Corporation, Karlsruhe, Germany). The temperature loggers measured temperature from 0 to +45 °C with an accuracy of ±0·3 °C and a resolution of 0·2 °C. The water bath contained 3·5 l of water adjusted to 37 °C. Temperature loggers were programmed to record measurements in 1-min intervals. Twelve observations were made at each degree increment from 37 to 44 °C with a defined 7±1-min incubation period to validate 24 loggers. The water bath temperature was measured with the calibrated liquid-in-glass thermometer and used as a reference method. Before initiating this experiment the lag period between the temperature sensor of water bath and temperature of the liquid in-glass thermometer was determined. The average lag period was between the stabilization of sensor temperature of water bath and the reference method temperature was 1±1-min. To assure correct measurements of temperature we decided to use 7±1-min incubation period after each temperature increase (i.e. 37·0–44·0 °C in 1·0 °C increments.
For studying agreement between RT and VT two experiments were conducted in vivo using the temperature loggers validated in Experiment 1.
Experiment 2
This experiment was performed with 11 lactating [135±56, days in milk (DIM); mean±sd] healthy, post-partum, multiparous, non-pregnant cows at the Clinic for Animal Reproduction, Freie Universität Berlin, Germany. Before enrolment the health status of the cows was evaluated on the bases of 2 months of disease and treatment records and cows were clinically examined on the day of enrolment. Only cows which had not been diagnosed or treated for infectious or metabolic or both diseases were enrolled. In mid-lactation BT of cows remained in the normal range (i.e. 37–39 °C; Kendall & Webster, Reference Kendall and Webster2009). All cows were housed in a tie stall barn with deep bedding (i.e. chopped straw and lime) and fed twice daily with grass-silage, grass hay, and concentrate and mineral mix.
Experiment 3
Vickers et al. (Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010) demonstrated that early post-partum cows have greater body temperature than peak lactation cows. Considering these differences, and since the nature of Experiment 2 did not allow us to draw inference on cows with elevated BT, another experiment was performed including twelve early post-partum (3±1, DIM) multiparous cows at a commercial dairy farm in Sachsen-Anhalt in Germany.
All cows were housed in a free stall facility with slotted floors and equipped with rubber mats. The cows were fed a total mixed ration consisting of 41·9% concentrate and mineral mix, 31·2% corn silage, 24·4% grass silage and 2·5% barley straw on a dry matter basis (net energy for lactation, NEL=7·03 MJ/kg dry matter) distributed with a conveyer belt system 10 times a day. Cows were milked 3 times daily.
During both experiments performed in vivo, ambient temperature (AT) and relative humidity (RH) of the experimental pen were recorded every minute using a Tinytag Plus II logger (Gemini loggers Ltd, Chichester, West Sussex, UK) which was secured at a beam 3 m above the ground. The temperature humidity index (THI) was calculated according to the equation reported by Kendall et al. (Reference Kendall, Tucker, Dalley, Clark and Webster2008): THI=(1·8×AT+32)–{(0·55−0·0055×RH)×(1·8×AT−26)}.
In Experiments 2 and 3, temperature loggers were set to record temperature at 1-min intervals. For VT monitoring temperature loggers were attached to a progesterone-free modified vaginal controlled internal drug release (Pfizer Animal Health, Berlin, Germany; CIDR) and inserted into the vaginal cavity. For RT monitoring temperature loggers were inserted into the rectum without a CIDR after removing the manure with a lubricated gloved hand. After insertion of the loggers into the vagina and rectum, the first 10 min of observations of temperatures were removed to assure that confounding due to lag effect of the logger due to influx of ambient air was eliminated. If vaginal and rectal loggers were retained inside at least 20±10 min an epidural injection of 2·5 ml of Procain (2% Procasel, Selectavet, Dr Otto Fischer; GmbH, Weyarn-Holzolling, Germany) was administered to prevent rectal and vaginal pressing. If both temperature loggers were retained at least for 80±10 min after epidural injection data were used for analyses. There is evidence (Skarda & Muir, Reference Skarda and Muir1979; Day & Skarda, Reference Day and Skarda1991) that epidural anaesthesia changes the blood flow. However in our preliminary analyses we did not observe any effect on BT.
Statistical analysis
To minimize statistical bias for Experiments 2 and 3 the required sample size was calculated using G*Power software (http://www.psycho.uni-duesseldorf.de/abteilungen/aap/gpower3/download-and-register). Considering previous studies (Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010; Burfeind et al. Reference Burfeind, Suthar, Voigtsberger, Bonk and Heuwieser2011; Suthar et al. Reference Suthar, Burfeind, Patel, Dhami and Heuwieser2011) we hypothesized that the minimum achievable association between RT and VT in dairy cows would be 0·8 at α=0·05 and β=0·05 level. Thus the minimum sample size for these experiments was 9 cows. Therefore 11and 12 cows were enrolled, respectively in Experiments 2 and 3.
Data from temperature and THI loggers were downloaded into excel spreadsheets (Office 2010, Microsoft Deutschland GmbH, Munich, Germany) and analysed using SPSS for Windows (Version 19.0, IBM Inc., IBM-Allee, Ehningen, Germany) and Medcalc (Version 12.0.3.0. MedCalc software, bvba, Mariakerke, Belgium). Rectal and vaginal temperature values 10 min after insertion and 10 min before removal of temperature loggers, respectively, were considered artefacts due to confounding by ambient temperature after logger movements and were excluded from the analyses.
The relationship between paired temperature observations of 24 loggers and the liquid-in-glass thermometer (reference method) was evaluated using Pearson's coefficient of correlation and linear regression whereas the mean difference was evaluated using a paired t test. The logger level variation and relationship was explained using intra-class correlation coefficient. The relationships between AT, RH and THI with RT and VT, respectively were evaluated using Pearson's coefficient of correlation for the two experiments performed in vivo. The influence of AT, RH and THI on RT and VT of cows in Experiments 2 and 3 were tested in univariate analyses considering them as covariates. Relationship between VT and RT in the two experiments performed in vivo was evaluated using Pearson's coefficient of correlation and linear regression, respectively. Due to the fact that comparison of clinical measurements using coefficients of correlation can be inappropriate, the agreement between the temperature observations of 24 temperature loggers and the liquid-in-glass thermometer in Experiment 1 (in vitro) and between VT and RT observations in Experiment 2 and 3 (in vivo) were graphically analysed using the method described by Bland & Altman (1986). It is also true that simple Pearson's correlations do not adequately describe the relationship between RT and VT measured with identical loggers within cows. One could get high correlations if cows varied in BT even if there was not a strong correlation between RT and VT within a cow. Therefore to compare agreement between RT and VT measures of individual cows of the two experiments performed in vivo the intra-class correlation coefficients using two-way mixed effects model, where RT and VT logger effects are taken as random and RT and VT observations effects are taken as fixed, were used. As per Field (Reference Field2005) we interpreted intra-class correlation coefficient such as, 0–0·2 poor agreement; 0·3–0·4 fair agreement; 0·5–0·6 moderate agreement; 0·7–0·8 strong agreement and >0·8 almost perfect agreement.
Potential difference between RT and VT observations of cows in Experiment 2 and 3 (in vivo) was evaluated repeating observations (paired observations of RT and VT of cow) over period of time and random effect of cow was included in both models. Scaled identity covariance structure was used, because it resulted in the models with the lowest Akaike information criterion value. The LSD post-hoc procedure was performed to estimate the difference between RT and VT observations of cows in Experiment 2 and 3. The reported statistics were performed according to guidelines supplied by Watson & Petrie (Reference Watson and Petrie2010).
Results and discussion
Considering logger as the experimental unit, 96 paired observations per logger were generated and used to validate the temperature loggers in vitro (Experiment 1). The mean difference between the values recorded by the temperature loggers and the liquid-in-glass thermometer was significant but practically negligible (0·06±0·1 °C, P<0·001). Also, there was a strong relationship between the temperature of the water bath measured with the liquid-in-glass thermometer and the recorded temperature of the loggers (r=0·996, P<0·001; R 2=992, P<0·001). Inter-logger variation was small (CV=0·005). The agreement between the paired observations of the gold standard and the 24 temperature loggers is shown in Fig. 1. The difference between temperature observations of the liquid-in-glass thermometer and the 24 loggers was negligible 0·04±0·1 °C (95% CI:−0·16 to 0·24 °C; Fig. 1). Furthermore we used intra-class correlation coefficient to evaluate an aggrement between temperatures of individual 24 loggers with liquid-in-glass thermometer (logger level). It demonstrated perfect agreements (intra-class correlation coefficient=1; P<0·001).
After excluding 10 min of paired observations, after logger insertion and before logger removal, an average 169±34 and 167±16 paired observations of RT and VT of individual cows could be used for analyses of Experiment 2 and 3, respectively. Ambient temperature and RH was 17·2±0·1 °C and 67·0±0·8%, and 12·6±0·1 °C and 83·0±0·2% in Experiments 2 and 3, respectively. The calculated THI in Experiments 2 and 3 were 62·0±1·0 and 57·5±0·2, respectively. Relationships between BT and THI in the two experiments in vivo did not exist (RT: r=−0·005, P=0·824; r=−0·071, P<0·001 and VT: r=0·002, P=0·948; r=−0·10, P=0·01). Furthermore, in both the experiments an influence of AT, RH and THI on RT and VT of experimental cows was not detected (P<0·5) and was removed from further analyses. The absence of relevant relationships between BT and THI is typical for relatively cool environmental conditions compared with other studies conducted in tropical climate (Kendall et al. Reference Kendall, Nielsen, Webster, Verkerk, Littlejohn and Matthews2006).
The mean (±sd) 38·77±0·23 °C RT and 38·78±0·24 °C VT was recorded in dairy cows of Experiment 2 whereas 39. 54±0·53 °C RT and 39. 48±0·49 °C VT was recorded dairy cows of Experiment 3. Overall, VT demonstrated 0·01±0·1 °C greater temperature compared with RT in Experiment 2 (P<0·001), whereas VT demonstrated 0·01±0·1 °C lower temperature compared with RT of cows in Experiment 3 (P<0·001). Associations between RT and VT existed during Experiment 2 (n=1861 paired observations, r=0·92, P<0·001; R 2=0·84, P<0·001; Figs. 2 & 3) and Experiment 3 (n=2003 paired observations; r=0·94, P<0·001; R 2=0·89, P<0·001; Figs. 4 & 5). The intra-class correlation coefficient between RT and VT observation measured with identical loggers within cows ranges from 0·4 to 0·94 (P<0·001) in Experiment 2. Specifically, 2 cows demonstrated moderate (0·4–0·6) and 9 other cows demonstrated strong to perfect agreements (intra-class correlation coefficient >0·7; P<0·01). Interestingly in cows with greater BT (38–41·4 °C) of Experiment 3, intra-class correlation coefficient between RT and VT loggers within cows ranges from moderate (0·6) to perfect (1·0; P<0·001). More specifically, 10 cows demonstrated strong (0·7–0·8) to excellent (⩾0·9) agreements, only 2 cows demonstrated moderate (0·6) agreements between RT and VT observations measured with identical loggers within cows. These results suggest that an agreement between RT and VT measured with identical loggers within cows during Experiment 2 and 3 is very high.
The associations between RT and VT measured using identical loggers during both experiments performed in vivo in this study were greater than those reported for early post-partum cows (r=0·81; Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010), peak lactation cows (r=0·46; Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010), ante-partum cows (r=0·76–0·89; Burfeind et al. Reference Burfeind, Suthar, Voigtsberger, Bonk and Heuwieser2011), and pregnant cows (r=0·84; 180±5 d; Suthar et al. Reference Suthar, Burfeind, Bonk, Dhami and Heuwieser2012b). As we expected, the correlation and regression analysis of this study revealed that the BT values measured in the rectal and vaginal cavities using the identical temperature loggers is strongly associated in different stages of lactation (Experiment 2: 135±56 DIM; Experiment 3: 3±1 DIM). To visualize the distribution of differences between RT and VT Bland-Altman plots were used (Figs. 2 & 4). In Experiment 2, the difference between RT and VT observations was 0·01±0·1 °C with −0·2 to 0·18 °C of 95% CI of lower and upper limit of difference (Fig. 2). Only 71 observations (3·8%) were outside the 95% CI. Because in Experiment 2 only healthy post-partum cows with normal BT (38·4–39·2 °C) were enrolled no inference could be made regarding the agreement between RT and VT for cows with greater temperature. Therefore in Experiment 3, 12 cows with greater temperature (mean RT 39·5 °C and VT 39·5 °C; BT range 38·0 to 41·4 °C) were enrolled. The difference between RT and VT observations was 0·06±0·2 °C (95% CI:−0·28 to 0·4 °C; Fig. 4). Only 93 (4·7%) observations were outside the 95% CI. We suspect that the wider range of the 95% CI in Experiment 3 was due to an enlarged vaginal cavity in early post-partum cows (3±1 DIM; Sheldon et al. Reference Sheldon, Williams, Miller, Nash and Herath2008; Kahn & Line, Reference Kahn and Line2010). The observation that in early post-partum cows VT was negligibly (0·1±0·1 °C) lower than RT (Experiment 3), whereas VT was negligibly (0·01±0·1 °C) greater than RT in cows later in lactation (Experiment 2) might also be related to a more frequent influx of outside air due to a calving-mediated suboptimal closure of the vulva.
Most recently, Burdick et al. (Reference Burdick, Carroll, Dailey, Randel, Falkenberg and Schmidt2012) reported higher correlation (r=0·97; P<0·001) utilizing 5 Brahman heifers between continuously measured RT and VT but with two different temperature loggers. The vaginal logger (Star-Oddi, DST micro-T logger, Meter Mall USA, Marysville OH, USA) was attached to a CIDR while the rectal logger, (TidbiT v2, Part UTBI-001, Onset Corp., Pocasset MA, USA) was fitted to an aluminium tail harness holding the temperature logger in place developed by Reuter et al. (Reference Reuter, Carroll, Hulbert, Dailey and Galyean2010). The above mentioned study describes the coefficient of correlation (r) between the results of the two measurement methods utilizing two different types of loggers as an indicator of agreement. However, it has been demonstrated that in the analysis of measurement method comparison correlation coefficients or regression analysis alone are inappropriate (Altman & Bland, Reference Altman and Bland1983; Bland & Altman, Reference Bland and Altman2010). Such measures should be complemented by a plot of difference against the average which is more useful in almost all applications to medical measurements (Bland & Altman, Reference Bland and Altman1986). Use of an identical method (i.e. temperature loggers) to measure RT and VT in cows and interpreting their results with Bland & Altman graphical agreement and intra-class correlation coefficients in this study shows a greater agreement for RT and VT than the previous studies.
Vickers et al. (Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010) and Suthar et al. (Reference Suthar, Burfeind, Patel, Dhami and Heuwieser2011) used hand-held digital thermometers to measure RT, whereas in the current study RT and VT were measured using technically identical temperature loggers. Our data demonstrated a greater correlation and agreement between RT and VT in individual animals. These results suggest that devices with different accuracy and resolution could have affected the results in previous studies. Vickers et al. (Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010) concluded that various changes in penetration depth, logger movement and air influx, and thermometer type could contribute to differences found between RT and VT. Temperature loggers in the current study were inserted at a minimal depth of 20±5 and 14±3 cm, respectively, into the rectum and the vagina. It can be suggested that a minimal depth of penetration for temperature measuring devices is necessary in order to minimize the influence of environmental factors.
Temperature loggers have been used in livestock research for decades. To our knowledge this is the first study which compared VT and RT with identical temperature measuring devices while previous studies used thermometers or rectal temperature monitoring device (Burdick et al. Reference Burdick, Carroll, Dailey, Randel, Falkenberg and Schmidt2012) to measure RT and temperature loggers in the vaginal cavity (e.g. Kendall et al. Reference Kendall, Nielsen, Webster, Verkerk, Littlejohn and Matthews2006; Vickers et al. Reference Vickers, Burfeind, von Keyserlingk, Veira, Weary and Heuwieser2010). We assume that the use of different measuring devices affected the results in those studies. Overall, continuous VT monitoring can provide a close measure of BT since coefficient of correlation and an agreement was high and differences between VT and RT were negligible.
We thank the staff of the Department of Biochemistry, Faculty of Veterinary Medicine, Freie Universität, Berlin, Germany for providing necessary laboratory facilities for the part of study performed in vitro and the cooperation of the farm personnel during the part of study carried out in vivo.