Waterborne Pathogen Detection More than Just “Location, Location, Location…”

Published online by Cambridge University Press:  10 May 2016

Brooke K. Decker
Affiliation:
Critical Care Medicine Department, National Institutes of Health Clinical Center, Bethesda, Maryland
Tara N. Palmore*
Affiliation:
National Institute of Allergy and Infectious Diseases and National Institutes of Health Clinical Center, National Institutes of Health, Bethesda, Maryland
*
National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD (tpalmore@mail.nih.gov)
Rights & Permissions [Opens in a new window]

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Commentary
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2014

References

1. Cristina, ML, Spagnolo, AM, Casini, B, et al. The impact of aerators on water contamination by emerging gram-negative opportunists in at-risk hospital departments. Infect Control Hosp Epidemiol 2014;35(2):122129 (in this issue).Google Scholar
2. Heffelfinger, JD, Kool, JL, Fridkin, S, et al. Risk of hospital-acquired legionnaires' disease in cities using monochloramine versus other water disinfectants. Infect Control Hosp Epidemiol 2003;24(8):569574.Google Scholar
3. Best, M, et al. Legionellaceae in the hospital water-supply: epidemiological link with disease and evaluation of a method for control of nosocomial legionnaires' disease and Pittsburgh pneumonia. Lancet 1983;2(8345):307310.CrossRefGoogle ScholarPubMed
4. Halabi, M, et al. Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp. J Hosp Infect 2001;49(2):117121.Google Scholar
5. van der Mee-Marquet, N, et al. Non-touch fittings in hospitals: a procedure to eradicate Pseudomonas aeruginosa contamination. J Hosp Infect 2005;60(3):235239.Google Scholar
6. Stout, JE, et al. Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: a national surveillance study with clinical correlations. Infect Control Hosp Epidemiol 2007;28(7):818824.CrossRefGoogle ScholarPubMed
7. Cross, DF, Benchimol, A, Dimond, E.G. The faucet aerator: a source of Pseudomonas infection. N Engl J Med 1966;274(25): 14301431.Google Scholar
8. Kappstein, I, et al. Aerators as a reservoir of Acinetobacter junii: an outbreak of bacteraemia in paediatric oncology patients. J Hosp Infect 2000;44(1):2730.Google Scholar
9. Weber, DJ, et al. Faucet aerators: a source of patient colonization with Stenotrophomonas maltophilia . Am I Infect Control 1999; 27(1):5963.Google Scholar
10. Muyldermans, G, et al. Neonatal infections with Pseudomonas aeruginosa associated with a water-bath used to thaw fresh frozen plasma. J Hosp Infect 1998;39(4)309314.Google Scholar
11. L'eau dans les etablissements de sante. Paris: Ministere de la Sante et des Solidarites, 2005.Google Scholar
12. Hota, S, et al. Outbreak of multidrug-resistant Pseudomonas aeruginosa colonization and infection secondary to imperfect intensive care unit room design. Infect Control Hosp Epidemiol 2009;30(1):2533.Google Scholar
13. Lowe, C, et al. Outbreak of extended-spectrum β-lactamase-producing Klebsiella oxytoca infections associated with contaminated handwashing sinks. Emerg Infect Dis 2012;18(8):12421247.CrossRefGoogle ScholarPubMed
14. Kool, JL, et al. More than 10 years of unrecognized nosocomial transmission of Legionnaires' disease among transplant patients. Infect Control Hosp Epidemiol 1998;19(12):898904.CrossRefGoogle ScholarPubMed
15. Sehulster, L, Chinn, RYW. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). MMWR Recomm Rep 2003;52(RR-10):142.Google ScholarPubMed