Hostname: page-component-745bb68f8f-grxwn Total loading time: 0 Render date: 2025-02-05T11:19:47.307Z Has data issue: false hasContentIssue false

Enhanced disinfection leads to reduction of microbial contamination and a decrease in patient colonization and infection

Published online by Cambridge University Press:  31 July 2018

William A. Rutala*
Affiliation:
Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina, United States Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, North Carolina, United States
Hajime Kanamori
Affiliation:
Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, North Carolina, United States Infection Control and Laboratory Diagnostics, Internal Medicine, Tohoku University, Sendai, Japan
Maria F. Gergen
Affiliation:
Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina, United States
Lauren P. Knelson
Affiliation:
Division of Infectious Diseases, Duke Center for Antimicrobial Stewardship and Infection Prevention, Duke University Medical Center, Durham, North Carolina, United States
Emily E. Sickbert-Bennett
Affiliation:
Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina, United States Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, North Carolina, United States
Luke F. Chen
Affiliation:
Division of Infectious Diseases, Duke Center for Antimicrobial Stewardship and Infection Prevention, Duke University Medical Center, Durham, North Carolina, United States
Deverick J. Anderson
Affiliation:
Division of Infectious Diseases, Duke Center for Antimicrobial Stewardship and Infection Prevention, Duke University Medical Center, Durham, North Carolina, United States
Daniel J. Sexton
Affiliation:
Division of Infectious Diseases, Duke Center for Antimicrobial Stewardship and Infection Prevention, Duke University Medical Center, Durham, North Carolina, United States
David J. Weber
Affiliation:
Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina, United States Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, North Carolina, United States
*
Author for correspondence: William A. Rutala, PhD, MPH, CIC, Division of Infectious Diseases, UNC School of Medicine, Bioinformatics Building, CB#7030, 130 Mason Farm Road, Chapel Hill, NC 27514-7030. E-mail: brutala@med.unc.edu
Rights & Permissions [Opens in a new window]

Abstract

In this prospective study, we monitored 4 epidemiologically important pathogens (EIPs): methicillin-resistane Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), Clostridium difficile, and multidrug-resistant (MDR) Acinetobacter to assess the effectiveness of 3 enhanced disinfection strategies for terminal room disinfection against standard practice. Our data demonstrated that a decrease in room contamination with EIPs of 94% was associated with a 35% decrease in subsequent patient colonization and/or infection.

Type
Concise Communication
Copyright
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved. 

Over the last decade, substantial scientific evidence has accumulated that contamination of environmental surfaces in hospital rooms plays an important role in the transmission of several epidemiologically important pathogens (EIPs); methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), Acinetobacter spp, and Clostridium difficile.Reference Otter, Yezli, Salkeld and French 1 Noncritical environmental surfaces and medical equipment surfaces are defined as those that contact intact skin. These surfaces may become contaminated with infectious agents and may contribute to cross transmission by acquisition of transient hand carriage by healthcare personnel (HCP) with subsequent transfer to patients. Thus, disinfection of the noncritical environmental surfaces and medical equipment surfaces is an essential component of infection prevention.Reference Donskey 2 Disinfection should render surfaces and equipment free of pathogens in sufficient numbers to prevent disease transmission.Reference Rutala and Weber 3 Because cleaning and disinfecting of environmental room surfaces is often inadequate,Reference Carling 4 the use of no-touch automated methods of disinfection (eg, ultraviolet C [UV-C]) has been studied using primarily before-and-after design studies.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce 5

In this study, we analyzed additional microbiological data from the Benefits of Enhanced Terminal Room (BETR) Disinfection StudyReference Anderson, Chen and Weber 6 to assess the effectiveness of 3 enhanced methods of room decontamination (ie, quaternary ammonium manual disinfection [Quat] followed by ultraviolet light [UV], bleach, or bleach plus UV) compared to a standard method (ie, Quat alone) to reduce the level of surface contamination with 4 epidemiologically important pathogens (ie, multidrug-resistant [MDR] Acinetobacter, C. difficile, MRSA, VRE) if they were present only in patient rooms, only in the bathroom, or in both. These organisms are ideal markers to study bacterial transmission in the hospital setting and were chosen due to their importance as pathogens in healthcare-associated infections (HAIs),Reference Magill, Edwards, Bamberg, Beldavs and Dumyati 7 and the propensity to contaminate and persist on hospital room surfaces.

Methods

This substudy of the BETR Disinfection Study was a pragmatic, prospective, multicenter, cluster-randomized trial that evaluated 4 different strategies for terminal room disinfection in 9 hospitals from April 2012 through July 2014.Reference Anderson, Chen and Weber 6 , Reference Chen, Knelson and Gergen 8 We performed microbiological analysis of randomly selected “seed” rooms to determine the total and average number of colony-forming units (CFU) of the 4 target organisms that remained in the patient room following terminal room decontamination at 3 study hospitals in central North Carolina: Duke University Hospital, a 921-bed tertiary-care academic medical center; Duke Regional Hospital, a 250-bed community hospital; and Duke Raleigh Hospital, a 148-bed community hospital. A seed room was defined as a single-patient room from which a patient on contact precautions was discharged or transferred.

The Duke University Health System Institutional Review Board approved this study, and it was registered on ClinicalTrials.gov as NCT01803100.Reference Anderson, Chen and Weber 6

Subject enrollment

We prospectively identified subjects with an anticipated hospitalization of >48 hours using the admission/discharge/transfer dataset of the electronic medical record. All patients admitted into newly cleaned and disinfected rooms at participating hospitals were eligible. Informed consent was obtained for study subjects.Reference Anderson, Chen and Weber 6 , Reference Chen, Knelson and Gergen 8

Specimen collection

The sampling was done as described in the BETR study publication.Reference Anderson, Chen and Weber 6 In brief, at each study visit, microbiological samples were collected from 8 of 10 environmental surfaces in the hospital room of the enrolled subject; these surfaces included the bed rail, over-bed table, supply or medicine cart, chair, sink, toilet seat, shower floor, side counter, linen hamper lid, and bathroom floor.Reference Anderson, Chen and Weber 6 , Reference Chen, Knelson and Gergen 8 , Reference Huslage, Rutala, Gergen, Sickbert-Bennett and Weber 9 Each surface area was sampled in a different location using 10 individual replicate organism detection and counting (Rodac) plates (Becton Dickinson, Franklin Lakes, NJ) to enhance microbiological yield and to reduce sampling error: 5 Rodacs for aerobic culture (~125 cm2) and 5 for anaerobic culture (Anaeropack, Mitsubishi Gas Chemical). Each Rodac plate sampled ~25 cm2. Microbiological analyses and identification were performed using standard protocols.Reference Anderson, Chen and Weber 6 , Reference Chen, Knelson and Gergen 8 We attempted to sample 25 rooms for each EIP: MRSA, VRE, Acinetobacter, and C. difficile. No other selection criteria were used. In total, 92 rooms were sampled: Quat disinfection (ie, the standard, 21 rooms), Quat plus UV (28 rooms; Tru-D, Memphis, TN), bleach (23 rooms), and bleach plus UV (20 rooms). The total number of Rodac plates for all 92 rooms was 7,360.

Microbiological methods

Dey/Engley (D/E) Neutralizing Agar (Becton Dickinson) or C. difficile selective agar was used on the Rodac plates. The D/E plates were incubated at 37°C for 48 hours; C. difficile plates were incubated anaerobically. Two quantitative microbiologic outcomes were determined: CFUs on each plate for each of the EIPs studied and the total CFUs of all EIPs studied. For C. difficile, only the total number of CFUs of C. difficile present on each plate was determined. In either scenario, the number of targeted pathogens was quantified by first identifying morphologies suggestive of the target organisms. These colonies were then subcultured and identified using standard microbiological methods.Reference Anderson, Chen and Weber 6 Statistical significance was determined by the Wilcoxon test, and P≤.05 was considered significant.

Results

The mean CFUs for each EIP studied and the total of all EIPs for each of the 4 room decontamination methods are displayed in Table 1.

Table 1 Epidemiologically Important Pathogens (EIPs) by Intervention and Contamination in 92 Patient Rooms During the Benefits of Enhanced Terminal Room Disinfection Study

Note. CFU, colony-forming units; Quat, quaternary ammonium compound; MDR, multidrug resistant; MRSA, methicillin-resistant Staphylococcus aureus; VRE, vancomycin-resistant Enterococcus; UV, ultraviolet light.

a Statistical significance was determined using the Wilcoxon test for an enhanced group (ie, Quat plus UV, bleach, or bleach plus UV) compared to a standard group Quat. P values are shown only when P<.05.

b EIPs include MDR-Acinetobacter, MRSA, VRE, and C. difficile. Table displays the CFUs by pathogen and decontamination method for surfaces in the patient room, bathroom, and room plus bathroom.

c Data on mean CFU per room in patient room or bathroom were published by coauthorsReference Rutala and Weber 3 and reanalyzed with additional data (ie, patient only, bedroom only).

Quat plus UV (an enhanced disinfection intervention) was significantly superior to Quat alone (standard method) in reducing EIPs in the patient room, bathroom, and patient room plus bathroom. In addition, Quat plus UV significantly reduced MRSA, VRE, and MDR Acinetobacter in the patient room plus bathroom, and it reduced MDR Acinetobacter and MRSA in the bathroom alone (Table 1). The other 2 enhanced methods (ie, bleach and bleach plus UV) led to a decrease in EIPs, but these reductions did not reach statistical significance compared to Quat alone. We detected no statistical difference between bleach and bleach plus UV in reducing C. difficile for any surfaces (ie, patient room only, bathroom only, or patient room plus bathroom).

As reported in the BETR study, comparing the best strategy with the worst strategy for reducing EIPs in a patient room plus bathroom, revealed that a reduction of 94% in EIPs (Quat, 60.8 CFU per room vs Quat plus UV, 3.36 CFU per room) led to a 35% decrease in colonization and/or infection (Quat, 2.3% vs Quat plus UV, 1.5%) (Table 2).

Table 2 Relationship Between Microbial Reduction of Epidemiologically Important Pathogens (EIPs) and Colonization and/or Infection in a Patient Subsequently Admitted to a Room of a Patient Colonized and/or Infected with an EIP by Decontamination Method

Note. CFU, colony forming units; Quat, quaternary ammonium compound; UV, ultraviolet light. Reduction in an enhanced method is calculated compared to standard method.

a Data on mean CFU per room of EIPs and colonization and/or infection rate were published by coauthors,Reference Rutala and Weber 3 then a reanalysis was done in which each reduction was calculated and compared in this study.

Discussion

The contaminated surface environment in patient rooms has been demonstrated to be a risk factor for the development of HAIs.Reference Otter, Yezli, Salkeld and French 1 , Reference Rutala and Weber 3 , Reference Carling 4 Multiple studies have demonstrated that improved room cleaning and disinfection reduces HAIs.Reference Donskey 2 Finally, more than a dozen intervention trials have now demonstrated that the use of a “no-touch” technology (eg, UV or vaporized hydrogen peroxide) for terminal room decontamination reduces HAIs.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce 5 However, most published studies for terminal room decontamination and HAI reduction used a before-and-after design and often failed to assess potential confounders such as hand hygiene compliance and cleaning effectiveness.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce 5 Further, all of these studies compared only 2 room decontamination methods.Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce 5 The BETR Disinfection Study was a cluster-randomized prospective trial designed to assess 3 different enhanced methods of room decontamination to a standard method, as well as to monitor potential confounders such as hand hygiene compliance and room cleaning.Reference Anderson, Chen and Weber 6

This study demonstrated that an enhanced method of room decontamination (ie, Quat plus UV) was superior in reducing room surface contamination with EIPs compared to a standard method (ie, Quat alone). The BETR Disinfection Study demonstrated that the rate of colonization and/or infection in a patient subsequently admitted to a room of a patient colonized and/or infected with an EIP was related to the decontamination method used: Quat, 2.3%; Quat plus UV, 1.5%; bleach, 1.9%; and bleach plus UV, 2.2%.Reference Anderson, Chen and Weber 6 Our finding that Quat with UV was superior to chlorine or chlorine with UV has been previously discussed and may be related to improved cleaning compliance and study power.Reference Anderson, Chen and Weber 6

In summary, this analysis adds further support to the key finding in the BETR disinfection study: enhanced environmental disinfection leads to decreased room contamination, which translates to decreases in subsequent patient colonization and/or infection. Multiple papers have shown that enhanced disinfection leads to a reduction in microbial contamination.Reference Donskey 2 Similarly, multiple papers have described enhanced disinfection that resulted in reduction of HAIs.Reference Donskey 2 , Reference Weber, Rutala, Anderson, Chen, Sickbert-Bennett and Boyce 5 However, to our knowledge, the BETR disinfection studyReference Anderson, Chen and Weber 6 and this analysis of the BETR disinfection study data are the first that quantitatively describe the entire pathway whereby enhanced disinfection decreases microbial contamination, which in turn reduces patient colonization and infection. Further, we have shown that several enhanced methods of room decontamination were significantly superior to a standard cleaning method. Therefore, we believe that hospitals should use an enhanced terminal disinfection method for contact precaution patient rooms to reduce the risk of HAIs originating in the environment.

Acknowledgments

Financial support

The CDC Prevention Epicenters Program (grant no. NCT01579370).

Conflicts of interest

Drs Rutala and Weber are consultants for Professional Disposables International (PDI) in 2017–2018 and were consultants for Clorox in 2012–2016. Dr Weber is a consultant for Germitec.

Footnotes

Cite this article: Rutala WA, et al. (2018). Enhanced disinfection leads to reduction of microbial contamination and a decrease in patient colonization and infection. Infection Control & Hospital Epidemiology. 2018, 39, 1118–1121. doi: 10.1017/ice.2018.165

References

1. Otter, JA, Yezli, S, Salkeld, JA, French, GL. Evidence that contaminated surfaces contribute to the transmission of hospital pathogens and an overview of strategies to address contaminated surfaces in hospital settings. Am J Infect Control 2013;41:S6S11.Google Scholar
2. Donskey, CJ. Does improving surface cleaning and disinfection reduce health care-associated infections? Am J Infect Control 2013;41:S12S19.Google Scholar
3. Rutala, WA, Weber, DJ. Monitoring and improving the effectiveness of surface cleaning and disinfection. Am J Infect Control 2016;44:e69e76.Google Scholar
4. Carling, P. Methods for assessing the adequacy of practice and improving room disinfection. Am J Infect Control 2013;41:S20S25.Google Scholar
5. Weber, DJ, Rutala, WA, Anderson, DJ, Chen, LF, Sickbert-Bennett, EE, Boyce, JM. Effectiveness of UV devices and hydrogen peroxide systems for terminal room decontamination: Focus on clinical trials. Am J Infect Control 2016;44:e77e84.Google Scholar
6. Anderson, DJ, Chen, LF, Weber, DJ, et al. The benefits of enhanced terminal room (BETR) disinfection study: a prospective, cluster randomized, multicenter, crossover study to evaluate the impact of enhanced terminal room disinfection on acquisition and infection caused by multidrug-resistant organisms. Lancet 2017;389:805814.Google Scholar
7. Magill, SS, Edwards, JR, Bamberg, W, Beldavs, ZG, Dumyati, G, et al. Multistate point-prevalence survey of healthcare-associated infections. New Engl J Med 2014;370:11981208.Google Scholar
8. Chen, LF, Knelson, L, Gergen, M, et al. A prospective study of transmission of multi-drug resistant organism (MDRO) between environmental sites and hospital patients-The TransFER study. Submitted for publication.Google Scholar
9. Huslage, K, Rutala, WA, Gergen, MF, Sickbert-Bennett, EE, Weber, DJ. Microbial assessment of high-, medium-, and low-touch hospital room surfaces. Infect Control Hosp Epidemiol 2013;34:211212.Google Scholar
Figure 0

Table 1 Epidemiologically Important Pathogens (EIPs) by Intervention and Contamination in 92 Patient Rooms During the Benefits of Enhanced Terminal Room Disinfection Study

Figure 1

Table 2 Relationship Between Microbial Reduction of Epidemiologically Important Pathogens (EIPs) and Colonization and/or Infection in a Patient Subsequently Admitted to a Room of a Patient Colonized and/or Infected with an EIP by Decontamination Method